BRAND | Stahl |
Product | 9195/08H-YO3-06V1 |
Description | Base for 8 dividers |
Internal code | 4863163 |
Discover the superior quality and performance of the Stahl 9195/08H-YO3-06V1 with RADWARD LTD in United Kingdom . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The 9195/08H-YO3-06V1 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of 9195/08H-YO3-06V1 :
At RADWARD LTD , we offer the 9195/08H-YO3-06V1 at competitive prices and with the fastest delivery times across United Kingdom . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose RADWARD LTD ?
Get Your Quote Today! Ready to enhance your operations with the 9195/08H-YO3-06V1 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Stahl products, RADWARD LTD is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
01644E0G 8003 PTB 01 ATEX 1129U
pushbutton
HOLDER,LAMP,PIN,240VAC,40W Material Contact : STANDARD Power Rated : 40 W Voltage, Rated : 240 VAC Type, Lamp Cap : PIN Basic Data Text : RIGHT SOCKET,FLOURESCENT LAMP
Cable Glands made of moulded plastic with strain relief explosion-protected Type : HSK-K-MZ-Ex Thread size : M16 x 1.5 Thread length : 15 mm Material : Polyamide / Aluminium Clamping range : 4 ... 8 mm2 Wrench size : A/F19 Application range (Zone) : 1 , 2 , 21 , 22 Type of protection (IP) : IP68 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 1 D Ex tD A20 Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Cable Glands Made of Moulded Plastic with Strain Relief Series HSK-K-MZ-Ex, explosion protected Thread AG: M16 x 1.5 Cable dia. range [mm]: 4 ... 8 For use in: Zones 1 & 2, 21 & 22
Cable Glands made of moulded plastic with strain relief explosion-protected Type : HSK-K-MZ-Ex Thread size : M20 x 1.5 Thread length : 15 mm Material : Polyamide / Aluminium Clamping range : 6 ... 12 mm2 Wrench size : A/F24 Application range (Zone) : 1 , 2 , 21 , 22 Type of protection (IP) : IP68 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 1 D Ex tD A20 Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Cable Glands Made of Moulded Plastic with Strain Relief Series HSK-K-MZ-Ex, explosion protected Thread AG: M20 x 1.5 Cable dia. range [mm]: 6 ... 12 For use in: Zones 1 & 2, 21 & 22
Two-pin fluorescent lamp
(Sodium high-pressure lamp 400W, tubular form)
6000/521-8011-3130 Lighting with 2-pin 1x18/20W
Lighting with 2-pin 1x18/20W Light Fittings for Fluorescent Lamps Series EXLUX 6000, explosion protected Lamps Number of lamps: 1 Lamp wattage: 18 W Monitoring module: without Material Enclosure: Polyester resin, glass fibre-reinforced / Colour white, similar to RAL 9010 Lamp cover: Polycarbonatean aromatic-resistant paint can be used For use in: Zones 1 & 2, 21 & 22 CCT No.: 94054035 DE Net weigth: 4,100 KG
6000/522-9011-0130 Light fitting with 2pin 18/20W
(Breather M25)
(Through wiring DV5 20W accessorie)
(Through wiring DV5 65W accessorie)
(Insert plate 2xM25x1,5 accessories)
Lamp socket
Repair Kit 36W electronic ballast + Accessories
6108/1081-8017-74-00 Compact emergency light fitting 1x8W
Auxiliary lens, clear
Lead-gel Battery with fuse;4 V;3.5 Ah
Main lamp(halogen lamp), 4.0 V;2 W; packing unit 2 pc’s
Economy lamp 3.7 V; 1.1 W; packing unit 10 pc’s
(Hand lamp explosion-protected Type : 6147/2-2 Enclosure material : Light metal Protective glass material : Temperature-resistant pressed glass Lamp wattage : 25 W, 40 W, 60 W Rated operational voltage AC : 230 V Rated operational voltage DC : 230 V, 24 V, 42 V Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T.. Dust explosion protection : II 2 D Ex tb IIIC 145 °C Min. ambient temperature : -20 °C Max. ambient temperature : +40 °C Type of protection (IP) : IP65 Connection : 1 x M20 mit Zugentlastung)
6388/1-2-2 Bulkhead light fitting Bulkhead Light Fitting Series 6388, explosion protected Lamps: up to 150 W Colour of glass: clear For use in: Zones 1 & 2
6508/1081-8017-74-00 Compact emergency light fitting 1x8W
Fluorescent luminaire explosion proof housing material: Polyester resin When Material: Polycarbonate Number of lamps: 2Lampenleistung: 18 WBemessungsbetriebsspannung AC: 240 VBemessungsbetriebsspannung DC: 254 VEinsatzbereich (zones): 2, 21, 22Gasexplosionsschutz: II 3 G Ex nA IIC T4Staubexplosionsschutz: II 2 D Ex tb IIIC 80 ° CUmgebungstemperatur min , : Max -25 ° CUmgebungstemperatur. : +55 ° CSchutzart (IP): IP66Durchverdrahtung: without closing plug: 2 x M25 x 1,5Für further information see: www.stahl.de Webcode 6600ALeuchte luminaire series ECOLUX 6600, explosion-protected lamp fitting lamp number: 2Lampenleistung: 18 WElektronisches gear: 1 channel EVGÜberwachungsbaustein: without through-wiring: without / case material: polyester resin, fiberglass-reinforced, color white, similar to RAL 9010Wanne: polycarbonate protective paint möglichEinsetzbar in: zones 2, 21 & 22
(Fluorescent luminaire, Type: 6600/52.-....-...., Specifications: Gas explosion: II 3 G Ex nA II T4 dust - Explosion protection: II D 2 T 80 ° C Test Certificate: DMT 01 E 085 / E ATEX 086X Suitable for: Fluorescent lamp 2Stift, 1 x 18W Reflector design symmetric wide distribution Material: Polyester resin surface: Without color IP 66 Ambient temperature: -20 ° C ... 55 ° C Rated voltage: QTP Osram: 220 V ... 240 V -10% + 10%; 50/60 Hz Cable entry: 2 x cable entry M25x1.5 1 x sealing plug M25x1.5 without bulbs Through wiring with 5 wires)
(Light fitting for fluorescent lamps explosion-protected Type : 6600/542-8010-2230 Enclosure material : Polyester resin Lamp cover material : Polycarbonate Number of lamps : 2 Lamp wattage : 36 W Rated operational voltage AC : 240 V Rated operational voltage DC : 254 V Application range (Zone) : 2 , 21, 22 Gas explosion protection : II 3 G Ex nA IIC T4 Dust explosion protection : II 2 D Ex tb IIIC 80 °C Min. ambient temperature : -25 °C Max. ambient temperature : +55 °C Type of protection (IP) : IP66 Through wiring : without Connection : 1 x M25 x 1,5 Plug : 2 x M25 x 1,5 CCT No.: 94054035 DE Net weigth: 5,000 KG)
(MontageschieneZubehoer)
(WandbefestigungswinkelZubehoer)